Факультет прикладних комп'ютерних технологій (ДМетІ) <br> Дніпровський металургійний інститут (ДМетІ)
Permanent URI for this community
UK: Факультет прикладних комп'ютерних технологій (ДМетІ)
Дніпровський металургійний інститут (ДМетІ) EN: Faculty of Applied Computer Technology
Dnipro Metallurgical Institute
Дніпровський металургійний інститут (ДМетІ) EN: Faculty of Applied Computer Technology
Dnipro Metallurgical Institute
Browse
Browsing Факультет прикладних комп'ютерних технологій (ДМетІ) <br> Дніпровський металургійний інститут (ДМетІ) by Author "Berlov, Oleksandr V."
Now showing 1 - 5 of 5
Results Per Page
Sort Options
Item CFD Modeling of Traffic-related Air Pollution in Street Canyon(Printing House “Technologija”, Kaunas, Lithuania, 2024) Biliaiev, Mykola M.; Biliaieva, Viktoriia V.; Berlov, Oleksandr V.; Kozachyna, Vitalii A.; Kozachyna, Valeriia V.; Yakubovska, Zinaida M.ENG: High pollution levels are often observed in urban street canyons. Different mathematical models are intensively used to predict pollution levels in urban street canyons. In this paper quick computing 3D CFD model is proposed to compute wind flow over buildings and pollutant dispersion in street canyon. To simulate wind flow over buildings 3D equation of potential flow has been used. Pollutant concentration field has been modelled using three-dimensional equation of pollutant dispersion. Governing equations are also included simplified equations to describe pollutants chemical transformations in atmosphere. To solve numerically governing equations implicit difference schemes have been used. The computer code to realize the proposed numerical models has been developed. Results of numerical experiments are presented.Item Modeling Influence of TiO2 Barrier Coating on Pollutant Dispersion Near Road(Kaunas University of Technology, 2023) Biliaiev, Mykola M.; Berlov, Oleksandr V.; Biliaieva, Viktoriia V.; Kozachyna, Vitalii A.; Kozachyna, Valeriia; Yakubovska, Zinaida M.ENG: Mitigation strategies for near-road air pollution are of great interest nowadays. Sound barriers near the road are very effective to decrease pollutant concentration. The use of titanium dioxide (TiO2) barrier coating provides additional effect which allows to decrease pollutant concentration near road. In this study quick- computing CFD model was developed to access influence of TiO2 barrier coating on pollutant concentration. To simulate wind flow over barrier with TiO2 coating model of potential flow was used. The process of NOx dispersion from car was computed using mass conservation equation. Finite-difference schemes were used for numerical integration of governing equations. The computer code was developed on the basis of proposed numerical model. Results of numerical simulations are presented.Item Prediction of Atmospheric Air Pollution Near a Coal Stack in Adverse Weather Conditions(IOP Publishing Ltd, 2023) Biliaieva, Viktoriia V.; Berlov, Oleksandr V.; Kozachyna, Vitalii A.; Nochvai, Volodymyr; Yakubovska, Zinaida M.; Oladipo, Mutiu OlatoyeENG: Coal piles on the territory of enterprises are long-term sources of dust pollution of atmospheric air. Forecasting the level of dust pollution of the air for such objects is carried out, as a rule, for convection conditions. But during inversion, very high concentrations of dust can occur on industrial sites. The task of assessing the level of dust pollution of atmospheric air at an industrial site during dust emission in conditions of inversion from a coal stack is considered. A three-dimensional equation of convective-diffusion dispersion of contamination in atmospheric air, compatible with the approach of Prof. Berliand M. on determining the value of the vertical diffusion coefficient in the surface layer of the atmosphere for the case of inversion, to model dispersion of dust from a coal stack under inversion conditions is used. Numerical integration of the modeling equation of convective-diffusion transport of contamination is carried out on the basis of the splitting method compatible with the use of a locally one-dimensional finite-difference scheme. The results of a computational experiment to determine dust pollution zones at the Prydniprovsk thermal power station are presented.Item Quick computing CFD model to predict chemical pollution in room(Український державний університет науки і технологій, Дніпро, 2025) Biliaiev, Mykola M.; Biliaieva, Viktoriia V.; Berlov, Oleksandr V.; Kozachyna, Vitalii A.; Mashykhina, Polina B.ENG: Purpose. The problem of accidental contamination of workspaces attracts special attention, since in the event of such extreme situations, intense chemical contamination of the air in work areas occurs. This poses a threat of toxic exposure to workers. When assessing the consequences of such situations, it is necessary to take into account the time factor, in particular, to quickly determine the creation of concentrations of chemically hazardous substances. In this regard, an urgent task is to develop effective mathematical models for rapid assessment of the consequences of extreme situations in the working areas of chemically hazardous facilities. The paper considers a CFD model for analyzing the process of chemical air pollution in a workspace during an accidental release of a chemically hazardous substance. The solution of the problem is based on the numerical integration of the fundamental equations of continuum mechanics. Methodology. To calculate the air velocity field in the working room during the operation of supply and exhaust ventilation, a mathematical model of the motion of an inviscid fluid was used. The equation of convective diffusion motion was used to calculate the concentration of a chemically hazardous substance in the workspace. The integration of the modeling equations was carried out using finite difference schemes. Findings. A dynamic model has been created to calculate the spread of a chemically hazardous substance in a work-space. On the basis of the built CFD model, a computer program was created to conduct a computational experiment. Originality. A CFD model has been created to predict the level of air pollution in a workspace in the event of toxic gas emissions. The model is based on the fundamental equations of aerodynamic mechanics and mass transfer. The model makes it possible to determine the effect of the ventilation mode, the intensity of emission of a chemically hazardous substance, the location of equipment in the workspace, and the dynamics of the formation of concentration fields. Practical value. The developed CFD model can be used to quickly analyze the consequences of accidental emissions of a chemically hazardous substance in a workplace and assess the risk of toxic exposure of workers.Item Simulation of Chemical Accident with Ammonia at the Pipe Line(Kaunas University of Technology, 2023) Biliaiev, Mykola M.; Berlov, Oleksandr V.; Biliaieva, Viktoriia V.; Kozachyna, Vitalii A.; Kozachyna, Valeriia; Mashykhina, Polina B.ENG: Ammonia is transported through Ukraine via the Togliatti-Odesa ammonia pipeline. The hostilities in Ukraine pose a risk of damage to this transportation system as a result of a shell, mine, etc. hitting the transportation system. Therefore, it is very important to predict the possible consequences of environmental pollution in the event of such an extreme situation. A numerical model was developed to solve this problem. The three-dimensional equation of convective-diffusive transport of an impurity in the atmosphere is used to predict the dynamics of pollution of atmospheric air and the underlying surface. Finite-difference splitting schemes are used to numerically integrate this equation. On the basis of the constructed numerical model, a computer code was developed to take into account the change in the intensity of ammonia leakage from the damaged pipeline. The results of a computational experiment are presented.